CTS.Targetis – Camera Target Scope

Camera test over long distances - sharpness with little space requirement

CTS Camera Target Scope

CTS.Targetis-Nano – maximum precision in the smallest space

Challenge

Cameras with a wide angle of view (30° or 70° FOV) are optimized for capturing distant objects. This is difficult to implement in real test environments – especially for end-of-line test benches. The test setup takes up a lot of space and is complex to align.

Solution

With the CTS.Targetis-Nano, we offer a compact, high-precision solution for the virtual representation of distant targets at very short distances. It enables reliable and space-saving tests directly in the production environment.

CTS.Targetis Nano function

Virtual imaging instead of test image over long distances

Key Benefits

  • Compact and portable – little space required, no long-distance targeting systems necessary, mobile and ready for immediate use.
  • High measuring accuracy – perfect alignment and testing of the camera optics.
  • Stable despite movement – only minimal effects due to lateral displacement – thanks to virtual distance of over 10 meters.
  • Efficient workflow – fast testing processes, simple integration, maximum reliability.
  • Flexible integration – ideal for EOL test benches, development labs and production lines. Can be used flexibly in a large number of development environments or within TZ.CATS (Camera Test System).

Conclusion

The CTS.Targetis nano solution optimizes your test environments and ensures more precise, faster and reproducible results – without complex installations at long distances. CTS.Targetis sets a new standard in quality assurance and revolutionizes long-range camera testing by combining precision, flexibility and compactness.

A look through the lens

Virtual depth – focus in the distance

Focus on the front plate

Focus on the front plate. The target for the TZ.CATS system appears 10 m–15 m behind the recording plate due to the virtual.

Focus on the target
Focus on the target (camera focuses to infinity).

Illumination of the Target

  • The CTS is designed to work optimally under the ambient light conditions intended for the TZ.CATS system. To achieve this, the CTS features two opaque diffuser panels (one on the top and one on the left side), each with 70% transmission.
  • The satinized surface of these panels creates a uniform, diffuse illumination inside the CTS, ensuring optimal lighting conditions for the metrological tasks of TZ.CATS and providing ideal target visibility.
  • If the available ambient lighting is limited (e.g., in a dark room) or if the CTS is partially shaded, it can be illuminated using an external light source (see example).
  • Due to the design of the CTS and TZ.CATS, no special lighting requirements need to be considered. However, a uniform illumination and consistent ambient brightness should be maintained for optimal performance.

Example: Illumination Methods

Focus on the front plate
CTS with ambient lighting – utilizes existing environmental light conditions for illumination.
Focus on the target
CTS with additional dedicated lighting – enhanced with an external light source to ensure consistent and uniform illumination.

Technical data

Compact version of the CamTargetScope series, designed for precise functional testing of cameras with a long range and a fixed focus set to infinity. The innovative optical design and robust target layout combine compact size with exceptional robustness and precision. Ideal for space-saving test setups that deliver reliable results on camera alignment and functionality.

Working Distance d (distance from camera front lens with 70° FOV to first surface lens of CTS)
Optics
- Entrance pupil D of CTS.Targetis-Nano
- Achromatic properties
- Virtual target distance
Target
- Target Size (inner dimensions)
- Outer dimension: (L x H x W)
Mounting
Target illumination
- Passive illumination from outside
- Optional active illumination
CTS.TARGETIS-Nano 77/+5D
1000-CTS0001_A
10 mm ≤ d ≤ 100 mm (with constraints and modified target up to 150mm)
D=77mm (Clear Aperture: 60 mm)
+5D
≥ 10 m
45 mm x 45 mm
approx. 245 mm x 100 mm x 100 mm
4 variable (longitudinally adjustable) sliding blocks along the bottom of the aluminum profile for attaching mounting brackets, each with 2 x M4 threads (sliding blocks height 10 mm above the floor)
Top cover plate and one side panel is opal (T ≥ 70 %), so that external lighting can be provided through the top plate
none
CTS.TARGETIS-Nano 48/+6.7D
1000-CTS0002_A
10 mm ≤ d ≤ 100 mm (max!)
D=48 mm (Clear Aperture: 45,7 mm)
+6.7D
≥ 5 m
24 mm x 24 mm
approx. 195 mm x 80 mm x 80 mm
4 variable (longitudinally adjustable) sliding blocks along the bottom of the aluminum profile for attaching mounting brackets, each with 2 x M4 threads (sliding blocks height 10 mm above the floor)
Top cover plate and one side panel is opal (T ≥ 70 %), so that external lighting can be provided through the top plate
none
Get in touch with us – our sales team will be happy to support you with your project